{"product_id":"2018-uniform-mechanical-code","title":"2018 Uniform Mechanical Code","description":"\u003ch2\u003e\u003cspan\u003e2018 Uniform Mechanical Code (UMC)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2018 Uniform Mechanical Code (UMC®)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides comprehensive requirements for the installation and maintenance of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eheating, ventilation, cooling, and refrigeration systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Developed through the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eANSI Consensus Process\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and designated as an American National Standard by the American National Standards Institute (ANSI), the 2018 UMC reflects modern practices and technologies in the mechanical industry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 2018 edition represents an important milestone in mechanical and HVAC standards, introducing specific provisions for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-flammability A2L and B2L refrigerants\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These refrigerants are associated with lower Global Warming Potential (GWP), making the 2018 UMC an important reference for professionals working with evolving refrigeration technologies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe code was developed with contributions from a broad range of industry stakeholders, including consumers, code officials, installers, maintenance professionals, manufacturers, laboratories, experts, and other users.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Updates in the 2018 Uniform Mechanical Code\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 2018 UMC includes significant updates and new requirements covering mechanical, HVAC, refrigeration, duct, hydronic, and fuel gas systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMechanical Systems \u0026amp; Exhaust\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eNew clearance requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esolid-fuel-burning appliances\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated requirements for ducts serving \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType I hood exhaust systems\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNew provisions for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eproduct-conveying ducts\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNew requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eType I and Type II exhaust systems\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eDuct Systems \u0026amp; Air Distribution\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eNew duct system sizing provisions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003educt leakage testing requirements\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRevised installation and closure requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eflexible air ducts\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNew provisions for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair dispersion systems\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFurnaces \u0026amp; Pressure Regulators\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eNew requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure regulators\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectric furnaces\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eRefrigeration Systems\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eNew requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eA2L and B2L low-flammability refrigerants\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erefrigeration machinery room\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requirements\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRequirements addressing machinery room access, openings, detectors, and ventilation systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNew provisions for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure-limiting devices for compressors\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHydronic Piping Systems\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eNew \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure testing requirements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for piping and components\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eexpansion tanks\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNew requirements covering materials used in hydronic systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eFuel Gas Piping Systems\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epiping materials\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eNew and revised \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoverpressure protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provisions\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUpdated requirements for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egas piping installation\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ACCA","offers":[{"title":"New Book - Soft Cover \/ No Practice Exam \/ No Pre-Printed Tabs","offer_id":51786554802409,"sku":null,"price":102.4,"currency_code":"USD","in_stock":true},{"title":"New Book - Soft Cover \/ No Practice Exam \/ Add Pre-Printed Tabs","offer_id":51786554835177,"sku":null,"price":117.39,"currency_code":"USD","in_stock":true},{"title":"New Book - Soft Cover \/ Add Practice Exam \/ No Pre-Printed Tabs","offer_id":51786554867945,"sku":null,"price":127.39,"currency_code":"USD","in_stock":true},{"title":"New Book - Soft Cover \/ Add Practice Exam \/ Add Pre-Printed Tabs","offer_id":51786554900713,"sku":null,"price":142.39,"currency_code":"USD","in_stock":true},{"title":"Highlighted and Tabbed Book - Soft Cover \/ No Practice Exam \/ No Pre-Printed Tabs","offer_id":51786554933481,"sku":null,"price":152.4,"currency_code":"USD","in_stock":true},{"title":"Highlighted and Tabbed Book - Soft Cover \/ Add Practice Exam \/ No Pre-Printed Tabs","offer_id":51786554966249,"sku":null,"price":177.39,"currency_code":"USD","in_stock":true},{"title":"New Book - Loose Leaf \/ No Practice Exam \/ No Pre-Printed Tabs","offer_id":51786554999017,"sku":null,"price":123.2,"currency_code":"USD","in_stock":true},{"title":"New Book - Loose Leaf \/ No Practice Exam \/ Add Pre-Printed Tabs","offer_id":51786555031785,"sku":null,"price":138.19,"currency_code":"USD","in_stock":true},{"title":"New Book - Loose Leaf \/ Add Practice Exam \/ No Pre-Printed Tabs","offer_id":51786555064553,"sku":null,"price":148.19,"currency_code":"USD","in_stock":true},{"title":"New Book - Loose Leaf \/ Add Practice Exam \/ Add Pre-Printed Tabs","offer_id":51786555097321,"sku":null,"price":163.19,"currency_code":"USD","in_stock":true},{"title":"Highlighted and Tabbed Book - Loose Leaf \/ No Practice Exam \/ No Pre-Printed Tabs","offer_id":51786555130089,"sku":null,"price":173.2,"currency_code":"USD","in_stock":true},{"title":"Highlighted and Tabbed Book - Loose Leaf \/ Add Practice Exam \/ No Pre-Printed Tabs","offer_id":51786555162857,"sku":null,"price":198.19,"currency_code":"USD","in_stock":true},{"title":"No Book \/ No Practice Exam \/ Add Pre-Printed Tabs","offer_id":51770393329897,"sku":null,"price":14.99,"currency_code":"USD","in_stock":true},{"title":"No Book \/ Add Practice Exam \/ No Pre-Printed Tabs","offer_id":51770393362665,"sku":null,"price":24.99,"currency_code":"USD","in_stock":true},{"title":"No Book \/ Add Practice Exam \/ Add Pre-Printed Tabs","offer_id":51770393395433,"sku":null,"price":39.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0094\/2175\/0372\/files\/2018_UMC_2__08457.webp?v=1788341780","url":"https:\/\/theexampros.com\/products\/2018-uniform-mechanical-code","provider":"The Exam Pros","version":"1.0","type":"link"}